X
  • No products in the list

MR5 ACTIVet Pro Laser – Multi Radiance Medical – DEMO

Exclusively used during Dispomed conferences. The most powerful, portable, and affordable therapeutic laser for Veterinary use, featuring Blue Light and 50 Watts of power.

  • 50W peak super pulsed power
  • Includes Multi Radiance’s 3 proven frequencies
  • 465 nm blue light for bacteria and wound management
  • Cordless
  • Rechargeable battery with up to 6 hours of continuous use
  • Non-invasive and drug-free
  • Shorter treatment times without raising skin temperatures
  • Protective travel silicone sleeve

The ACTIVet PRO provides a 300% increase in power which can shorten treatment times and provide powerful pain relief. Unlike High Powered Lasers, the increase in power of the ACTIVet PRO does not elevate the skin temperature making it the SAFEST HIGH POWERED LASER on the market. 1-Year Warranty (shipping fees not included).

Out of stock

SKU: 175-0295-PRO226-LIQ

The cordless, portable laser therapy system and successor to the ACTIVet™.

With 50 W of Super Pulsed Laser power, 300% more total power than its predecessor, and 900% more blue light, the ACTIVet PRO provides more power and faster treatment times without raising skin temperature, making it the safest high powered laser on the market.

The blue LED light accelerates wound repair and reduces bacteria in wounds, providing your pet with a safe, fast and drug-free recovery.

Multi Radiance technology has proven its technology works, without limitations. Our technology safely delivers the most light to deep tissue and facilitates absorption.

In clinical studies, Super Pulsed Lasers beat Class IV Lasers in safety, controlling inflammation mitigating pain, infection control and wound care, setting a new standard for veterinary laser therapy.

An increase in power can shorten treatment times and provide powerful pain relief. However, unlike high powered Class IV lasers, the ACTIVet PRO increases power without the unwanted photothermal effect, avoiding the production of excessive reactive oxygen species (ROS) that can lead to photocytotoxicity and apoptosis. Laser, like ultrasound, at low levels, can stimulate while at higher levels it becomes destructive.
The synchronous use of high power super pulsed laser, and ultra-bright infrared, red and blue LEDs optimizes the biological effects of the entire phototherapeutic window to accelerate healing and reduce pain.

Include Acupuncture Trigger Point Probes

  • Made of non-toxic, organic polished glass
  • Bend and focus light to smaller targeted areas
  • Easy to clean
  • Increase functionality of your laser without buying additional equipment
  • 4 probes: auricular, corporal, utility, dome acupuncture without needles

Included With The MR5 ACTIVet Pro Laser

  • ACTIVet PRO™ Emitter (50,000mW)
  • 2 Pairs of Laser Goggles
  • Carrying Case
  • Operating Manual
  • Treatment Protocol Manual
  • One set of 4 LaserPuncture Trigger Point Probes

Super Pulsed Laser

The Science of Super Pulsed Laser

What is Super Pulsed Laser Therapy and How Does it Work?

MR5 ACTIVET PRO

Laser radiation: 905 nm
Broadband infrared radiation: 860 nm
Visible red light radiation: 660nm
Visible blue light radiation: 465nm
Laser radiation peak pulse power: 50W
Laser pulse duration: 110±20 ns
Broadband infrared radiation average power: 250
Red light average power: 100 mW
Radiation aperture: 4±0,4 cm²
Magnetic induction: 35±10 mT
Overall dimensions: 203x64x70 mm
Net weight: 250 g

Electrical guide

12 volts / 5.8 amperes

Why Use Lasers For Veterinary Treatement?

Multi Radiance Medical’s Veterinary Laser Therapy devices provide accelerated pain relief and healing. This safe and powerful technology is applied with a cordless hand-held applicator providing targeted Super Pulsed Laser light that stimulates cell regeneration. Throughout the world, cold Laser Therapy is used to relieve acute/chronic pain, back pain, carpal tunnel, arthritis pain, fibromyalgia, tennis elbow, muscle strain, bursitis, tendonitis, and other injuries in humans; now we’re bridging the gap and offering safe and effective for all aspects of Veterinary care.

Multi Radiance Laser Therapy can be particularly helpful in reducing pain and enabling arthritic animals to be more active. It also is beneficial in managing wounds and dermatological abnormalities including hot spots, lick granulomas, otitis externa, pyoderma and healing of surgical incisions. If there is infection, blue light therapy can be used to reduce the bacterial load and minimize the need for anti-microbial therapy. Finally, Multi Radiance Laser Therapy can speed healing by decreasing pain and inflammation and promote blood flow to the affected areas.

MR5 ACTIVet Pro Laser Also Treats These Conditions

  • Pododermatitis
  • Bursitis and tendonitis
  • Gingivitis, stomatitis and tooth extractions
  • Rodent ulcers and feline acne
  • Cystitis
  • Feline asthma
  • Rhinitis, sinusitis
  • Trauma
  • Hip dysplasia
  • Pyotraumatic dermatitis (hot spots)
  • Inflammatory bowel disease
  • Dermatomyositis
  • Tail fractures
  • Acupuncture

Some conditions will improve with one or two treatments, such as post-surgery and acute pain, while other conditions may require a series of visits over a few weeks, like lick granulomas and otitis.

Download

Multi Radiance Lasers Brochure

Super Pulsed Laser Difference

Anchored in Science: The most optimal mechanism for laser treatment, providing maximum photonic density without hazardous thermal effect.

What Is True Super Pulsing?

Do not confuse the “pulsing” of continuous wave lasers with the super pulsed technology of Multi Radiance lasers. Continuous wave “pulsing” is accomplished literally by “chopping the beam”, i.e., mechanically turning the laser on and off. This not only limits the power and depth of penetration offered by continuous wave lasers, it also encourages the body to adapt to its effects, limiting its treatment ability.

With Multi Radiance technology, you can super pulse up to 50,000mW of power which is more than most Class IV lasers, yet with a higher degree of safety. The laser and electronic technologies required to use super pulsed diodes are more advanced and the diodes themselves are more expensive than the continuous wave diodes. This is probably why most lasers in the North American market are low powered Gallium Aluminum Arsenide continuous wave lasers.

Proven, Powerful, Safe and Effective

Multi Radiance Super Pulsed Lasers use innovative technology to deliver light energy to tissue, which reduces pain and increases circulation.

Cascading Energy Effect™ Multi Radiance Super Pulsed Lasers combine three clinically proven wavelengths to create the Cascading Energy Effect™, allowing for deeper penetration and enhanced absorption of light.

Cascade de lumière bleue - Thérapie au laser

Super Pulsed Laser

The super pulsed laser (905nm) produces high powered light in billionth-of-a-second pulses. The power of each pulse drives the photons deep into the target tissue. Multi Radiance Medical’s technology’s power of up to 50,000mW creates a high photon density, strongly reducing pain and improving micro-circulation.

Infrared SLDs

Pulsed broad band infrared emitting diodes (875nm) penetrate shallower tissue depths than the laser but provide a broader spectrum of coverage.

Pulsed Red LEDs

Pulsed red light (660nm) penetrates shallower depths.

Pulsed Blue LEDs

Pulsed Blue Light (465nm) superficial penetration.

Static magnetic field

Static magnetic field keeps ionized molecules of tissue in a dissociated state, enhancing the body’s potential to absorb energy.

Super Pulsing Is Key To Multi Radiance Technology

Super pulsed infrared laser (905 nm) GaAS is the essential component of Multi Radiance Medical technology. Multi Radiance Medical super pulsed lasers deliver billionths-of-a-second pulses, combined with up to 50,000 mW of peak power for a higher concentration of light energy, or photons, driven deeper into the target tissue without any risk of overheating.

Super pulsing allows for deeper penetration than a laser of the same wavelength that is not super pulsed but has the same average output power. This is because short pulses allow for quick absorption. In addition, the period between pulses promotes a better environment for optimal pain relief.

Super pulsed infrared laser penetrates deeply into target tissues and exerts powerful stimulating influences upon blood microcirculation. In general, laser diodes are either continuous wave or pulsed. The continuous wave diodes emit laser energy for the entire time they are electrically driven, hence the name. They provide a fixed level of power during emission. Super pulsed diodes emit a series (frequency) of radiation impulses with high amplitude in an extremely short duration (typically 100 to 200 nanoseconds). The mean output of power of a Multi Radiance Medical super pulsed laser will increase as the pulse repetition is increased.

Each impulse of the super pulsed laser produces high peak power delivered for a very brief duration. It is the high power level during each pulse that creates the energy density necessary to deliver adequate doses to the target tissue. Even though the pulse peaks at a high power level, there are no thermal effects in the tissue. Therefore, the peak power of a pulsed laser is high compared to its average output power. By using super pulsed lasers, one is able to more effectively deliver higher densities of light energy.

Advantages Of Super Pulsed Laser

  • More photonic energy
  • The advanced semi-conductor laser diode delivers higher power pulses of photonic energy in thousands of milliwatts without any deleterious heating of tissue.
  • Increases in peak power improve energy penetration into tissue
  • Super pulsed laser technology provides more energy and penetrates deeper than comparable non-super pulsed lasers but does not generate excessive damaging heat.
  • Maximum Photonic Density: the power density during these very high pulses yields an extremely high photon flux and saturation, delivering a stronger effect.
Technologie du Laser

LaserSweep™

Prevent tissue from adapting to treatment with our LaserSweep™ technology. The constant use of the same frequency, as found in duty cycle lasers, can cause the body’s tissue to adapt to the laser’s effects, thus limiting its therapeutic power. Therefore it is necessary to provide variable photobiostimulation to avoid tissue adaptation to the signaling frequency. The LaserSweep technology varies its frequency to prevent the tissue from adapting to frequency pulses.

LaserSweep™ is exclusive to Multi Radiance Medical and utilizes a range of frequencies that “sweep” from highest to lowest (from the fixed end points) during treatments. By varying the “frequencies” each laser impulse effectively changes the laser’s target depth of penetration. It is, in essence, “scanning” the target tissue from superficial to deep. Changes in the frequency not only impact the depth of the energy, but also the rate at which the energy is delivered. The combination of the “variable” depth and dose rate reduces risk of biological adaptation to treatments. No continuous wave or high powered Class IV laser can ever attempt this.

Target™

The LaserStim™ is the first and only FDA-cleared device to combine neuroadaptive electrical stimulation and laser in a single emitter, which allows clinicians to quickly locate and automatically deliver the appropriate energy dose to the affected areas. The LaserStim’s™ Treatment Area Recognition and Guidance Enhanced Technology™ (TARGET) provides an interactive neural stimulation by constantly measuring electroconductivity of treated tissue.

Target™ technology benefits:

  • Wider list of applications than traditional modalities
  • Synergistic effect of Multi Radiance therapy provides benefits of light and neurostimulations
  • Faster temporary pain relief
  • Assists a clinician in identifying the optimal treatment locations
  • Constantly changing impulses, preventing accommodation of tissue to neurostimulation

Cascading Energy Effect™

Multi Radiance Medical uses three clinically proven wavelengths: 660 nm, 875 nm and 905 nm to cover the entire spectrum therapeutic window of light for deeper penetration and enhanced absorption of light.

Our sophisticated software algorithm synergizes multiple wavelengths, creating a cascading effect: 660 nm absorbed by superficial tissue clears the way for infrared 875 nm to penetrate deeper and eliminate cellular interference, which allows infrared 905 nm super pulsed laser to go even deeper.

Multi Radiance Medical’s proprietary multi-source technology successfully manipulates the interaction between light, laser and magnetic energy fields to achieve the desired penetration in the target tissue area.

Dr. Debbie Torraca present the Multi Radiance lasers

How to use the MR4 ACTIVet Pro Super Pulsed Laser

Laser Therapy Protocol: Otitis & Ear Infections

Laser Therapy Protocol: Mouth, Gums, Dental | ACTIVet PRO

Laser Therapy Protocol: Swelling + Lymphatic Drainage | ACTIVet PRO

Laser Therapy Protocol: Osteoarthritis | ACTIVet PRO

Laser Therapy Protocol: Wound Management w/ Blue Light | ACTIVet PRO

Laser Therapy Protocol: Start with Unwind Protocol | ACTIVet PRO

Laser Therapy Protocol: Otitis & Ear Infections

The Science of Super Pulsed Laser

What is Super Pulsed Laser Therapy and How Does it Work?

NEED MORE INFORMATION?

Fill in this form and one of our experts will contact you shortly!