Short video to explain how and when to replace soda lime on Moduflex™ veterinary anesthesia machines. Video transcription Hi, welcome to another Dispomed video. Today we will be looking at how and when to replace the sodasoarb in your anesthesia machine. Soda lime is used to absorb the CO2. There is a colour indicator included … [Continue Reading]
Vaporizer Service Frequency
The anesthesia vaporizer is a critical component of your veterinary anesthetic machine. It is very important to ensure that the appropriate percentage of anesthetic agent is being delivered. A malfunctioning vaporizer can be the cause of inappropriate depth of anesthesia (e.g., animals under anesthesia too lightly or too deeply) and may also be the reason you “lose” … [Continue Reading]
The truth about dead space in a breathing circuit
A lot of confusion exists in veterinary practices concerning the definition of dead space in a breathing circuit. There are 2 types of dead space: Anatomical dead space Mechanical dead space Nothing can be done about anatomical dead space, as it is the patient. Mechanical dead space, however, must be kept to a minimum. Understanding … [Continue Reading]
Highdent Veterinary Dental Units Maintenance Guide
A properly maintained machine reduces air consumption and extends the life of the unit. Prerequisites: Air supply : 75 to 85 psi (5.5 bar) – Electrical : 110-240 vac (option). Daily Maintenance Procedure. *Lubricate the second larger hole of the high-speed handpiece daily and operate the handpiece for 10 seconds. The low speed handpiece can … [Continue Reading]
Hydraulic and Electric Tables Maintenance Guide
Hydraulic and electric tables require regular maintenance in order to extend their lifespan. We recommend this monthly maintenance in order to fully benefit from your equipment: Tables with wheels For tables with wheels, it is recommended to remove all animal hair that can accumulate on the wheels. The hair can create vibrations that can either … [Continue Reading]
Autoclave Maintenance Guide
At Dispomed, we know that a properly functional autoclave is an essential part of a safe practice, which is why we would like to share with you some technical tips to extend the life of your autoclave unit. Weekly maintenance Here are a few simple steps to a hassle-free cleaning with Chamber Brite. For better … [Continue Reading]
How to reduce hypothermia risks when performing a surgery under anesthesia?
Before talking about ways of reducing heat loss, do you know what hypothermia is? Hypothermia, when happening under anesthesia, is a drop in body temperature. There are 4 hypothermia stages; mild which is over 36.6°C (98°F), moderate from 35.6°C to 36.6°C (96°F to 98°F), Severe from 33.3°C to 35°C (92°F to 95°F) and critical below 33.3°C (92°F). Which techniques do … [Continue Reading]
Microscope Maintenance Guide
At Dispomed, we know that a properly maintained microscope is essential to a precise diagnosis. That is why we want to offer some advice that will increase the efficiency and the life of your microscope. Daily Maintenance We recommend the following steps after each use: Turn off the light. Remove all traces of oil from … [Continue Reading]
Why do I need a scavenger interface?
During surgery, the unused gas should be evacuated outside of the building to avoid it being inhaled by your employees and patients. Connected to a gas evacuation ventilator, the scavenger interface controls the flow of suction and maintains the balance along with the quantity of unused gas. If you don’t use a scavenger interface, you can … [Continue Reading]
Are you currently using a Combo dental delivery unit?
Do you find that you don’t enjoy doing dental procedures as much as you used to and find yourself refusing requests for dental treatments? Have you noticed damage to your patient’s teeth and gums during scaling? Do you find that scaling takes too long? The Combo polisher is not a high-speed handpiece; therefore, it tends … [Continue Reading]